v. Trigger Mode (60fps, Binning, 1/4 partial scanning)
Function
Mode
Frame
rate
Binnig
Scanning
Method
Trigger Mode
Reset Mode
Trigger
Polarity
Exposure
Start Mode
Gamma
Sync
System
Settings
10H
11H
12H
Trigger
60fps
ON
1/4 partial
scanning
Edge preset
Non-Reset
Positive
Normal
1.0
Internal
98H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
Negative
Normal
1.0
Internal
D8H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
V-Reset
Positive
Normal
1.0
Internal
99H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
Negative
Normal
1.0
Internal
D9H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
Pulse width
Non-Reset
Positive
Normal
1.0
Internal
B8H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
Negative
Normal
1.0
Internal
F8H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
V-Reset
Positive
Normal
1.0
Internal
B9H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H
Negative
Normal
1.0
Internal
F9H
82H
00H
External
02H
0.45
Internal
82H
01H
External
02H
H reset
1.0
Internal
82H
10H
External
02H
0.45
Internal
82H
11H
External
02H